How-to: Receive Acceleration Snippets ===================================== This example outlines the steps to connects to an ANURA vibration sensor and configures it to send acceleration waveform data in the form of snippets. 1. **Scan for the Device**: Scan to find the sensor node, which will be advertising the AVSS UUID. 2. **Connect and Subscribe**: Connect to the sensor and set up subscriptions to the Control Point and Report characteristics. 3. **Retrieve Firmware Info**: Execute the ``Get Firmware Info`` command and note the response. Although not mandatory, displaying this information can be useful for troubleshooting. 4. **Configure Settings**: Execute the ``Write Settings`` command and await the response. The sensor will ignore any unknown or malformed parameters, and the response will indicate the number of ignored parameters. 5. **Apply Settings**: Execute the ``Apply Settings`` command and await the response. If the sensor needs to reboot, the ``will_reboot`` parameter will be set. The client should handle this by reconnecting. 6. **Subscribe to Snippet Reports**: Execute the ``Report Snippets`` command to subscribe to snippet reports. 7. **Trigger Measurements**: Send a ``Trigger Measurement`` command to initiate measurements, even if the sensor is stationary. To extend the measurement period beyond the maximum of 60 seconds, issue repeated ``Trigger Measurement`` commands. These can be sent before the previous measurement period has ended.